Gumi SIP 3 House South Korea
Location: Ro Dong-gu, Daegu, South Korea
Project Information
| Project Type: | Residential, < 3,000 sq. ft. |
|---|---|
| Manufacturer: | |
| Builder: | HB Lowe Construction |
| Design Professional: | HB Lowe Construction |
| Year Built: | 2016 |
Performance
| High Performance: | Yes |
|---|---|
| HERS/EUI Index Score: | |
| ACH50 - Blower Test Results: | 0.8 |
| kBtu/sq.ft./year: | |
| CO2 lbs./sq.ft./year: |
SIPs saved a lot on labor and energy. Three different architectural material on the exterior wall: Ceramic siding, wood siding and zinc. Certifications completed: 1st class by Korea Institute of Building Energy Technology PHIK Index: Score 63 (Korea does not have a HERS Index). Blower door test results (ACH50) (residential projects): 0.8 ACH50. Heat recovery ventilation Energy form exhausted stale indoor air to temper incoming fresh air. Heat is retained during cooler season and moved during warmer seasons. This system captures about 77% of the energy already expanded to temper incoming air. Window frame and glass = Komerling 08Plus + Uf = 0.80w/m2k, triple glass 0.75 w/m4. 2 inch EZFS (exterior insulation and finish system) Insulating system door - Komerling System door: 0.88w/m2k Airtightness tape (window, SIPs joint) - proclima Teson Vana. LED lighting High efficiency condensing boiler. ECO - friendly flooring, wallpaper and paneling.
Documents
- Other: Gumi-SIP-3-House-Ro-Dong-gu-SK-Application.pdf
- Other: Gumi-SIP-3-House-Ro-Dong-gu-SK-Energy-Certificate.pdf