ENERGY STAR SIP House Madison WI
Location: Madison, WI
Project Information
Project Type: | Residential, < 3,000 sq. ft. |
---|---|
Manufacturer: | Energy Panel Structures |
Builder: | Ultimate Construction, Inc. |
Design Professional: | Energy Panel Structures, Inc. |
Year Built: | 2020 |
Performance
High Performance: | Yes |
---|---|
HERS/EUI Index Score: | 44 |
ACH50 - Blower Test Results: | 0.08 |
kBtu/sq.ft./year: | |
CO2 lbs./sq.ft./year: |
Awards/Certifications: ENERGY STAR Certified, EPA Indoor AirPLUS
BEA: Energy Star
Focus on Energy
We had built two houses in 2019 for this owner, a happy returning customer. SIPs were chosen due to our track record on energy levels and blower door numbers on previous houses that we have built with SIPs. Quietness and healthiness of the finished product. Had to change the logistics, efficiency and planning offsite, by bringing product onto jobsite daily. This was due to not having room onsite and no parking available.
Documents
- Building Plans: High-Performance-SIP-House-Madison-WI-Ultimate-Kavanaugh-1033-First-Floor-4-3-20.pdf
- Building Plans: High-Performance-SIP-House-Madison-WI-Ultimate-Kavanaugh-1033-Lower-Level-4-3-20.pdf
- Building Plans: High-Performance-SIP-House-Madison-WI-Ultimate-Kavanaugh-1033-Second-floor-4-3-20.pdf
- Other: High-Performance-SIP-House-Madison-WI-1033-Vilas-ResCheck-Final.pdf
- Other: High-Performance-SIP-House-Madison-WI-Air-Tightness-Kavanaugh_Spec-1033.pdf
- Other: High-Performance-SIP-House-Madison-WI-BuildingExcellenceForm_Kavanaugh_EPS.pdf
- Other: High-Performance-SIP-House-Madison-WI-Final-Reports-Kavanaugh-1033.pdf
- Other: High-Performance-SIP-House-Madison-WI-Final-Reports-Kavanaugh_Spec-1033.pdf
- Other: High-Performance-SIP-House-Madison-WI-Focus-on-energy-1033.pdf
- Other: High-Performance-SIP-House-Madison-WI-Summary-Report-Kavanaugh_Spec-1033.pdf