SIP Passive House Claverack NY
Location: Hudson, NY
Project Information
Project Type: | Residential, < 3,000 sq. ft. |
---|---|
Manufacturer: | |
Builder: | Bill Stratton Building Company |
Design Professional: | Timberline Panel Company, LLC |
Year Built: | 2011 |
Performance
High Performance: | No |
---|---|
HERS/EUI Index Score: | 52 |
ACH50 - Blower Test Results: | 0.15 |
kBtu/sq.ft./year: | |
CO2 lbs./sq.ft./year: |
Awards/Certifications: Building Excellence Awards, DOE Zero Energy Ready Home, ENERGY STAR Certified, EPA Indoor AirPLUS, Passive House
BEA: 2012 Single Family Homes - Under 3,000 sq. ft Winner
12" SIP walls and 12" Neopor SIP roof
HERS Index 52
Certified Passive House - First House in New York
0.15 ACH50
Passive solar design and operable skylights
HRV and two air source heat pumps
Serious 725 series windows
Documents
- Building Plans: SIP-Passive-House-Claverack-NY-HPP-Floor-Plans.pdf
- Other: SIP-Passive-House-Claverack-NY-Building-Excellence-Awards-App.pdf
- Other: SIP-Passive-House-Claverack-NY-HPP-Awards.pdf
- Other: SIP-Passive-House-Claverack-NY-HPP-Energy-Rating-Doc.pdf
- Other: SIP-Passive-House-Claverack-NY-HPP-Intro.pdf
- Other: SIP-Passive-House-Claverack-NY-HPP-Media-doc.pdf
- Other: SIP-Passive-House-Claverack-NY-HPP-Passive-Certification.pdf