• 253-858-7472

Carrington View Building A

West Kelowna, BC

Participant information

Insulspan
Stephen Munn
600 Chester Road, #1
Delta, BC 92234
Phone: 517-486-4844
Email Address: insulspan@insulspan.com
Website: www.insulspan.com

Category

Multifamily

High Performance: Yes

Project information

Carrington View Building A
2200 Majoros Road
West Kelowna, British Columbia, Canada V4T 2C2

Date Completed: November 2020

Dimensions of building (all floors of multi-story building): Ground floor, second floor, third floor, fourth floor : 67' 8" x 251' 0" Underground parkade: 67' 8" x 251' 0"

Total sq. ft. of conditioned space: 63,512 sq. ft.

Built By (if different than applicant)

Highstreet Ventures
William Monforton
702-1708 Dolphin Way
Kelowna, British Columbia, Canada  V1Y 9S4

Panels Manufactured By: Insulspan


Designed By (if different than applicant - SIPA will only recognize members)

WD Fisher Architect
W. D. Fisher
608 - 318 Homer Street
Vancouver, British Columbia, Canada V6B 2V2

Total sq. ft. of conditioned space: 63,512 sq. ft.

Describe the end use of the building:
Carrington View Building A is one of three buildings in this apartment complex in West Kelowna, British Columbia. This building has 64 rentals units (47 2-bedroom and 17 1-bedroom) that range in size from 614 sq. ft. to 913 sq. ft.

How did SIP construction help you get this job?
Carrington View Building A was developed as a net-zero ready building and targets the top step of the BC Energy Step Code. The building incorporates a SIP wall system for improved waste management as well as zero-carbon mechanical systems and on-site solar power generation.

SIP wall thickness and core material: 8¼" with Neopor EPS core

Describe the benefits of using SIPs on this project. Did SIPs help save time, labor, construction costs, or energy? Incorporating SIPs into this building project was an integral part of creating a tight building envelope which is necessary in a net-zero ready building. SIPs also decreased the amount of waste created on the job site.


Describe any innovative design elements or structural engineering involved:
Every design element of this building was first considered through the prism of "how does it help this project meet the target of net-zero ready?" Only after the team determined the element's usefulness in meeting the project's target was it implemented. That is how design elements like under slab insulation, high efficiency lighting, and the particular windows were selected.

Please list any certifications the project received, such as ENERGY STAR, LEED, National Green Building Standard, WELL, Passive House, Green Globes or local green building programs. Only list certifications that are completed:
With the building completion in late 2020, certifications are in process.

HERS Index: Not completed on this multi-fami

Blower door test results: The blower door test result is 0

Energy use intensity in kBtu/ft2:
Total Energy Use Intensity (TEUI

Describe the HVAC system used on the project:
Common Areas: Heat Pump MUA Heating and Cooling - Cooling EER: 11.8, Heating COP: 3.94 Parkade: Ventilation Only - 0.62 W/L/s
Suites: Carrier Intelli-Balance Heat Pump Heating & Cooling with inverter compressor; HRV - Panasonic Low-Temp Energy Recovery Ventilator

Describe any other energy-saving materials used in the building envelope other than SIPs. List U-values of windows used and the U or R-value of any insulation materials:
- All-Weather Triple-Pane 2100 Series Windows with HS6 Sunstop Glazing and Argon Fill for a U-value of 0.19 BTU/h.ft2.F
- All-Weather Steel Balcony Doors with HS6 Glazing on window lites for a U-value of 0.22 BTU/h.ft2.F
- 2" rigid insulation wrapping SIPs and on underground walls of parkade, R10.5 effective
- R30 spray-applied insulation on underside of slab/Parkade roof, R31.3 effective
- Highly insulated wood frame roof with R52 nominal value, R50.3 effective

Please list any energy-efficient products or design features, such as lighting, hot water heating, appliances, passive solar:
Carrington View Building A includes: high efficiency interior lighting, heat pump hot water tanks with a 3.42 COP (coefficient of performance), heat pump heating for corridors instead of electric resistance heat, and high efficiency extended range air-source heat pumps for unit conditioning.

Were any solar panels installed on the project? If so, indicate the size of the system:
Yes. The solar array covers the roof of Carrington View Building A. The array size is 99 kWP and will produce 102.7 MWh/year. This production level is enough power to heat, light, and cool the building's common areas.

 

Please list any sustainable materials or design features not listed above, such as recycled materials, low-VOC finishes, landscaping, etc.:Highstreet Ventures took a holistic building approach to Carrington View Building A. This approach covered everything from low-VOC paints to the sourcing of wood and building materials. It also included the creation of an on-site education program so the trades constructing the building would recognize how their work plays a key part in the measurable aspects of the building's performance.

Click on a photo to enlarge.

Builder Information

Highstreet Ventures
William Monforton702-1708 Dolphin Way
Kelowna, BC V1Y 9

Phone: 778.946.6250

Panels manufactured by Insulspan.

SIPA Website Sponsors